Report the ad
Panasonic Outdoor Unit U-6LA1E5-1 Air Conditioners - System Designing - 91982502 - Ahmedabad
Tuesday, 11 June, 2013Item details
City:
Ahmedabad, Gujarat
Offer type:
Sell
Price:
Rs 10
Item description
PREFERED DEALER
Panasonic
Ideas for life
AIRCONDITIONERS
SYSTEM DESIGNING
102 Aagam Complex
Nr. Vasna Tel. exchange
Pratapkunj
Ahmedabad india
Tfax.:- 91 79 26631673
Mobile 9825024651
E-mail :- sdesign_trs@yahoo.com
U-6LA1E5-1
6 HP
Cooling Capacity: 15.5 kW / 52,900Btu/h
Heating Capacity: 18.0 kW / 61,400Btu/h
Maximum Combination of Indoor Unit: 8
Features
Specifications
VRF Air Conditioning
The FS Multi is a variable refrigerant flow (VRF) system that uses a single outdoor unit to independently control multiple indoor units. By communicating with the indoor units, the outdoor unit controls the flow of refrigerant to each one of them to match their cooling or heating loads. This enables independent operation of each of the indoor units, with inverter control providing optimum energy-saving operation. Air conditioning in multiple rooms by a single outdoor unit also means much less construction and a big improvement in the appearance of buildings. And a wide range of indoor models is available to satisfy the needs of different kinds of buildings. Taking advantage of its extensive experience with models for both the home and commercial facilities, Panasonic is ready to provide the ideal air conditioning solution.
FS Multi Advantages
FS Multi&s cutting edge VRF technology is perfectly suited to medium-sized or small areas, with single-phase power sources, together with advanced lnverter technology, opening up previously unimagined possibilities in the world of air conditioning. Air conditioning spaces can now take on a new dimension. If you have bought a new property, residence, offices or commercial place which is still in the construction phase, or if you are refurbishing, Panasonic offers you the chance to enjoy FS Multi air conditioning.
Total freedom of choice. Up to 30 different indoor unit models. Allows you to choose the best option depending on architectural needs and decoration criteria.
Three outdoor unit ratings: 4, 5 and 6 H.P [I 1.2, 14.0, 15.5kW/38,000,48,000 and 53,000 Btu]., single-phase.
Inverter technologywith R410A refrigerant, "greater comfort and economywith lower consumption".
Greatest space reduction. Asingle outdoor unit feeds up to 8 indoor units [at 5HP and 6HP).
Ease of installation. Thanks to the reduced dimensions of the outdoor unit it can be taken to the roof of the building in the lift.
Refrigerant Charge-free System
The FS Multi is a refrigerant charge-free system (4.0 - 6.0HP Outdoor unit Only) that does not require a charge of additional refrigerant even when using a full pipe length of up to 90m. This dramatically shortens the installation time required for charging with additional refrigerant, weight measurement and pressure judgment. It also eliminates charge amount calculation and there&s less chance of a cooling capacity shortage due to an incorrect amount of refrigerant being used or other errors.
Pipes of Up to 90 M
The total length of the pipe between a system’s indoor and outdoor units can be extended up to 90 metres, with a height difference of up to 30 metres. These ample limits make it possible to place the outdoor unit on the roof. The maximum height difference between indoor units in the same system may be up to 15 metres, thus covering 4 or 5 floors in the same system.
Tejas Shah
919825024651
Panasonic
Ideas for life
AIRCONDITIONERS
SYSTEM DESIGNING
102 Aagam Complex
Nr. Vasna Tel. exchange
Pratapkunj
Ahmedabad india
Tfax.:- 91 79 26631673
Mobile 9825024651
E-mail :- sdesign_trs@yahoo.com
U-6LA1E5-1
6 HP
Cooling Capacity: 15.5 kW / 52,900Btu/h
Heating Capacity: 18.0 kW / 61,400Btu/h
Maximum Combination of Indoor Unit: 8
Features
Specifications
VRF Air Conditioning
The FS Multi is a variable refrigerant flow (VRF) system that uses a single outdoor unit to independently control multiple indoor units. By communicating with the indoor units, the outdoor unit controls the flow of refrigerant to each one of them to match their cooling or heating loads. This enables independent operation of each of the indoor units, with inverter control providing optimum energy-saving operation. Air conditioning in multiple rooms by a single outdoor unit also means much less construction and a big improvement in the appearance of buildings. And a wide range of indoor models is available to satisfy the needs of different kinds of buildings. Taking advantage of its extensive experience with models for both the home and commercial facilities, Panasonic is ready to provide the ideal air conditioning solution.
FS Multi Advantages
FS Multi&s cutting edge VRF technology is perfectly suited to medium-sized or small areas, with single-phase power sources, together with advanced lnverter technology, opening up previously unimagined possibilities in the world of air conditioning. Air conditioning spaces can now take on a new dimension. If you have bought a new property, residence, offices or commercial place which is still in the construction phase, or if you are refurbishing, Panasonic offers you the chance to enjoy FS Multi air conditioning.
Total freedom of choice. Up to 30 different indoor unit models. Allows you to choose the best option depending on architectural needs and decoration criteria.
Three outdoor unit ratings: 4, 5 and 6 H.P [I 1.2, 14.0, 15.5kW/38,000,48,000 and 53,000 Btu]., single-phase.
Inverter technologywith R410A refrigerant, "greater comfort and economywith lower consumption".
Greatest space reduction. Asingle outdoor unit feeds up to 8 indoor units [at 5HP and 6HP).
Ease of installation. Thanks to the reduced dimensions of the outdoor unit it can be taken to the roof of the building in the lift.
Refrigerant Charge-free System
The FS Multi is a refrigerant charge-free system (4.0 - 6.0HP Outdoor unit Only) that does not require a charge of additional refrigerant even when using a full pipe length of up to 90m. This dramatically shortens the installation time required for charging with additional refrigerant, weight measurement and pressure judgment. It also eliminates charge amount calculation and there&s less chance of a cooling capacity shortage due to an incorrect amount of refrigerant being used or other errors.
Pipes of Up to 90 M
The total length of the pipe between a system’s indoor and outdoor units can be extended up to 90 metres, with a height difference of up to 30 metres. These ample limits make it possible to place the outdoor unit on the roof. The maximum height difference between indoor units in the same system may be up to 15 metres, thus covering 4 or 5 floors in the same system.
Tejas Shah